-  * **If you power cycle the machine because of weird errors, you must leave the machine turned off for a //minimum// of 10 minutes**+**If you power cycle the machine because of weird errors, you must leave the machine turned off for a //minimum// of 10 minutes** 
 + 
 +----- 
 + 
 +====== Machine faults out with F303 Error in Feed Section of Flat Die Cut ====== 
 +{{ :resizedimage_2023-10-26_04-21-27_2002.jpg?400 |}} 
 + 
 +If you have this error on the HMI, you have to //simultaneously// press both green buttons (pictured below) to re-prime the lubrication lines and clear the error. 
 + 
 +{{ :2023-10-26_04_52_18.png?400 |}} 
 + 
 +The alarm will sound continuously for a few seconds while it goes through its cycle. 
 + 
 +Doing this once may not clear the error.  Operator repeated this cycle five times before error went completely away. 
 + 
 +Operator also stated that sometimes you have to push both green buttons, //and also//, the blue button between them, //simultaneously//
 + 
 + 
 +====== Outside suction cups on flexo section won't pop up ====== 
 +  * vanes are broken in one of the vacuum pumps 
 +  * the side guides are in too tight.  The large outer suction cups won't actuate if the side guides are in too close.