Trace:

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
dro_troubleshooting [2023/04/06 04:25] phildro_troubleshooting [2024/09/04 07:21] (current) phil
Line 1: Line 1:
 +  * **If you power cycle the machine because of weird errors, you must leave the machine turned off for a //minimum// of 10 minutes**
   * **AG stacker table extension will not retract/retracts //very// slowly**   * **AG stacker table extension will not retract/retracts //very// slowly**
     *  depth can't be greater than 19     *  depth can't be greater than 19
Line 7: Line 8:
   * [[Feeder vacuum fan VFD troubleshooting]]   * [[Feeder vacuum fan VFD troubleshooting]]
   * [[Production hit e-stop and now machine won't run]]   * [[Production hit e-stop and now machine won't run]]
 +  * [[Machine breaker turns off not due to high current]]
 +  * **Bundle breaker faults with break fault**
 +     * If the bundle is an irregular shape, when it breaks, it may not be clearing the photo eye in time.  You can //lower// the across measurement in the setup and it will fix this.