Differences
This shows you the differences between two versions of the page.
| Next revision | Previous revision | ||
| dro_troubleshooting [2023/01/14 13:18] – created phil | dro_troubleshooting [2024/09/04 07:21] (current) – phil | ||
|---|---|---|---|
| Line 1: | Line 1: | ||
| + | * **If you power cycle the machine because of weird errors, you must leave the machine turned off for a //minimum// of 10 minutes** | ||
| * **AG stacker table extension will not retract/ | * **AG stacker table extension will not retract/ | ||
| * depth can't be greater than 19 | * depth can't be greater than 19 | ||
| + | * **Secondary lift table will not lift up and down** | ||
| + | * BCS Auto Position needs to be turned on so both tables will raise for bundle breaker | ||
| + | * [[door limit won't light up]] | ||
| * [[compression section]] | * [[compression section]] | ||
| * [[Feeder vacuum fan VFD troubleshooting]] | * [[Feeder vacuum fan VFD troubleshooting]] | ||
| * [[Production hit e-stop and now machine won't run]] | * [[Production hit e-stop and now machine won't run]] | ||
| + | * [[Machine breaker turns off not due to high current]] | ||
| + | * **Bundle breaker faults with break fault** | ||
| + | * If the bundle is an irregular shape, when it breaks, it may not be clearing the photo eye in time. You can //lower// the across measurement in the setup and it will fix this. | ||